Warmlyyours Environ Flex Roll System For laminate/floating woo Manuale Utente Pagina 8

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 14
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 7
6
Installing The Thermostat
If you are using a thermostat with a oor sensor, place the sensor under the Environ™ Flex Rolls, centered between two heat wires, at least 6” (150 mm) into the
heated area.
Make a small divot in the underlayment in this spot and secure the sensor head in the divot with tape. Run the sensor cable in a channel cut into the underlayment
from the heater and back to the thermostat. The “heater wires” within the roll are identied as raised parallel lines. The sensor wire should not cross over the foil heater
wires, and is better placed in a channel cut into the underlayment, under the roll.
HOT
THERMOSTAT SENSOR
(LOW VOLTAGE)
FROM POWER SOURCE 120V & 240V
SENSOR
Front
PB112C-GA
1
2
ENSURE THE SYSTEM IS GROUNDED
HOT (240V) or
NEUTRAL (120V)
HOUSE GROUND
Red (240) or
Yellow (120) Wires
Red
Black
Red
Copper
Ground
4x4 Box
Black
Black Lead
THERMOSTAT
Load
S
L2 (N)
L1 (L)
E
F
RED
BLACK
SENSOR
GROUND
Vedere la pagina 7
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Commenti su questo manuale

Nessun commento